Search

Publications matching your search query

Results 2826 to 2850 of 5018

Ionospheric slab thickness and total electron content determined in Australia. ANARE Reports, 2001 (Ref: 10050)
Category 1: Peer-reviewed literature

Ionospheric Total Electron Content (TEC) determined from July 1991 to June 1995 is examined from southern Australia using Global Positioning System (GPS) satellite data recorded by the Defence Science and Technology Organisation at Salisbury, South Australia.

Dynamics of the polar cap ionosphere. Part 2. Case studies of polar patches above Casey, Antarctica. ANARE Reports, 2001 (Ref: 10046)
Category 1: Peer-reviewed literature

During 1997 and early 1998 a series of campaigns were undertaken at the Australian Antarctic polar cap station Casey (-80.8o geomagnetic latitude) with the aim of identifying and gaining further understanding of polar patches.

Dynamics of the polar cap ionosphere. Part 1. Applications of digisonde animations in ionospheric research. ANARE Reports, 2001 (Ref: 10044)
Category 1: Peer-reviewed literature

A UMLCAR ( University of Massachusetts Lowell, Centre for Atmospheric Research) Digital Ionosonde (DPS-4) has operated at the Australian Antarctic polar cap station Casey (80.8oS geomagnetic latitude) since early 1993, primarily to study the dynamics of the southern polar cap ionosphere.

Precursors of geomagnetic storms observed by the muon detector network. Journal of Geophysical Research, 2000 (Ref: 9592)
Category 1: Peer-reviewed literature

We report the first systematic survey of cosmic ray precursors of geomagnetic storms. Our data set comprises the 14 “major” geomagnetic storms (peak Kp >= 8–) identified by Gosling et al. (1990) together with 25 large storms (peak Kp >= 7–) observed from 1992 through 1998.

Muon Observations Book, "Cosmic Rays and Earth", Space Sciences Series of ISSI, 2000 (Ref: 9584)
Authors:
Category 1: Peer-reviewed literature

Muon observations are complementary to neutron monitor … observations but there are some important differences in the two techniques. Unlike neutron monitors, muon telescope systems use coincidence techniques to obtain directional information about the arriving particle.

Muon Observations Space Science Reviews, 2000 (Ref: 9546)
Authors:
Category 1: Peer-reviewed literature

Muon observations are complementary to neutron monitor observations but there are some important differences in the two … techniques. Unlike neutron monitors, muon telescope systems use coincidence techniques to obtain directional information about the arriving particle.

Nowcasting convection velocity in the high-latitude ionosphere using statistical models. Journal of Atmospheric and Solar-Terrestrial Physics, 1999 (Ref: 8763)
Category 1: Peer-reviewed literature

The Weimer and IZMEM statistical convection models are driven with a time series of interplanetary magnetic field (IMF) measurements made onboard the Wind spacecraft. The model outputs are used to infer convection velocity at Casey, Antarctica (80.8°S geomagnetic latitude)…

Signatures of the ionospheric cusp in digital ionosonde measurements of plasma drift above Casey, Antarctica Journal of Geophysical Research, 1999 (Ref: 8752)
Category 1: Peer-reviewed literature

Signatures of the ionospheric cusp in HF digital ionosonde measurements of plasma drift made at the polar cap station Casey, Antarctica (-80.8° geomagnetic latitude) are investigated. Measurements recorded during the campaign interval February 13-17…

Application of the Dopplionogram to Doppler-sorted interferometry measurements of ionospheric drift velocity Radio Science, 1999 (Ref: 8715)
Category 1: Peer-reviewed literature

The Dopplionogram was developed as a method of displaying Doppler shifts along the frequency axis of ionograms recorded using B-mode soundings of the Dynasonde, an early type of HF digital ionosonde.

A large Vertical Wind in the thermosphere at the Auroral Oval/Polar Cap Boundary seen simultaneously from Mawson and Davis, Antarctica. Journal of Atmospheric and Solar-Terrestial Physics, 1999 (Ref: 8819)
Category 1: Peer-reviewed literature

Ground-based Fabry-Perot spectrometer observations from the Australian Antarctic stations of Davis and Mawson show an upward wind ~100 m s-1 in the thermosphere at ~240 km altitude on the night of Day of Year 159 in 1997.

Thermospheric wind field over Mawson and Davis, Antarctica; simultaneous observations by two Fabry-Perot spectrometers of l630 nm emission. Journal of Atmospheric and Solar-Terrestrial Physics., 1999 (Ref: 8818)
Category 1: Peer-reviewed literature

The thermopheric oxygen l630 nm emission has been observed using high-resolution Fabry-Perot spectrometers at Mawson (67.6°S, 62.9°E) and Davis (68.6°S, 78.0°E), Antarctica. A new technique, combining the results from the two instruments, is used to derive vector wind fields.

The influence of polar-cap convection on the geoelectric field at Vostok, Antarctica Journal of Atmospheric and Solar-Terrestrial Physics, 2003 (Ref: 10749)
Category 1: Peer-reviewed literature

Vertical geoelectric eld measurements at Vostok,Antarctica (78:5ºS ;107ºE;corrected geomagnetic latitude,83:4ºS) made during 1998 are compared with both Weimer (1996)and IZMEM (1994)model calculations of the solar-wind-induced, polar-cap potential di erences with respect to the station.

on