Field trial of ion-exchange resin columns for removal of metal contaminants, Thala Valley Tip, Casey Station, Antarctica. Cold Regions Science and Technology, 2007 (Ref: 12932)
Category 1: Peer-reviewed literature

A field trial for removal of dissolved metal contaminants in water from an abandoned waste disposal site, using ion-exchange … columns of an iminodiacetic acid chelating ion-exchange (IDA) resin, was conducted at Casey Station, Antarctica. An on-site … monitoring technique…

Removal of metal contaminants by ion-exchange resin columns, Thala Valley tip, Casey Station, Antarctica. Solvent Extraction and Ion Exchange, 2006 (Ref: 12664)
Category 1: Peer-reviewed literature

Salinity and lowtemperature effects on adsorption of contaminant metals from … water using an iminodiacetic acid (IDA) ion-exchange resin, were investigated under … dynamic flow conditions. The order of selectivity of the resin (20°C and 0% seawater) was: Cu2+Pb2+Cr3+ Ni2+Cd2+Zn2+ Low temperature…

Removal of metal contaminants from saline waters at low temperature by an iminodiacetic acid ion-exchange resin, Thala Valley Tip, Casey Station, Antarctica. Solvent Extraction and Ion Exchange, 2005 (Ref: 12319)
Category 1: Peer-reviewed literature

Effects of salinity and low temperature on the removal of dissolved contaminant … metals from water by an iminodiacetic acid (IDA) ion-exchange resin, Amberlite … IRC748, were investigated under batch equilibrium conditions. As expected for ions … retained by chelation…

Water treatment to prevent contaminant dispersal during remediation of cold regions contaminated sites Cold Regions Science and Technology, 2007 (Ref: 12929)
Category 1: Peer-reviewed literature

Water collection and treatment is often required for effective cold regions contaminated site clean-up. Large volumes of … meltwater runoff can become contaminated during remediation activities and disperse pollutants into the surrounding environment.