Summary
Photometric intensity measurements of the OH(6-2) band P1(2), P1(3), P1(4) and P1(5) emissions were collected at a four minute repetition rate at Davis station, Antarctica during 1994. These data are being examined to determine the magnitude, percentage occurrence and duration of temperature fluctuations in the 15 minute to two hour period range. A report on the progress of the work is presented.
Authors:Williams P.F.B. Burns G.B. Lambert M. French W.J.R.
Publisher: Australian Antarctic Division
Published in: 2001
Category 1: Peer-reviewed literature
Program area: Space and Atmospheric Sciences
Williams P.F.B., Burns G.B., Lambert M., French W.J.R.
(2001)
A modern, initial attempt to determine temperatures from a rotating-filter photometer monitoring the major p-branch lines of the OH(6-2) band at Davis, Antarctica,
ANARE Reports
146.
115–123;
Related projects
Long-term monitoring of the mesopause region via hydroxyl emissions at Davis
FRENCH, Dr William (John)
Casey, Davis